Sansion Power Electric Co., Ltd.

Providing One-Stop Service For Customers

Manufacturer from China
Active Member
8 Years
Home / Products / AC Resonant Test System /

Cost Effective AC Resonant Test Set Transformer Use Protection System In Substation

Contact Now
Sansion Power Electric Co., Ltd.
City:wuhan
Province/State:hubei
Country/Region:china
Contact Now

Cost Effective AC Resonant Test Set Transformer Use Protection System In Substation

Ask Latest Price
Video Channel
Brand Name :Sansion Power
Model Number :SXBP
Certification :ISO, SGS, ilac-MRA, CNAS
Place of Origin :Wuhan, China
MOQ :1 Set
Price :Negotiation
Payment Terms :T/T, L/C, Western Union
Supply Ability :100 Sets Per Month
Delivery Time :15 Working Days
Packaging Details :Plywood Case
Specification :ISO9001 SGS
Oil Cylinder Position :Under
Control :Auto
Transport Package :Plywood Case
AC Withstand Test for :Electric Equipments of Substation at 10kv~500kv
Power Source :AC 110V/220V at Customized
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Substation Electrical Apparatus AC Resonant Test Systems Sxbp

General Information


SXBP Series AC Resonance Test System is specially designed for AC withstand test for electric equipments of substation at 10kV~500kV or below.

Applications

√ Transformer

√ Cables

√ CT/PT

√ GIS System

√ Insulator

Features

√ With over current, over voltage, IPM and discharge protection function.

√ Test result can be printed.

√ Small temperature rising at rated load. Dry-type epoxy cast, high mechanical strength and good insulation ability.

√ Screen to show the test data, status and display operation step by real-time.

√ Different type reactors for optional realize the multipurpose.

√ 220V or 380V single phase power source is suitable for on-site sourcing.

√ Small size, portable for operating.

Common Configuration

Model Test Object Main Configurations:
AC power source Exciting Transformer Reactor Capacitive Voltage Divider:

SXBP-27/54/108-108

Test Frequency: 20~300Hz

31500kVA/35KV Power Transformer 10KW 1 unit 10KW 1 unit

27KV/1A

4 Units

Frequency: 20-300Hz

120KV
35KV circuit breaker, busbar, insulator
10KV(300mm2) cable 2000m
35KV(300mm2) cable 500m

SXBP-54/108/216-216

Test Frequency: 20~300Hz

110KV Circuit breaker and busbar 15KW 1 unit 15KW 1 unit

54KV/1A

4 Units

Frequency: 20-300Hz

110KV GIS ≤ 10 intervals
35KV (300mm2) cable 1500m
10KV (300mm2) cable 3000m
110KV Full Insulated Transformer

SXBP-65/130/260-520

Test Frequency: 20~300Hz

110KV Circuit Breaker and busbar 30KW 1 Unit 30KW 1 Unit

65KV/2A 4 Units

Frequency: 20-300Hz

300KV
110KV GIS ≤ 10 intervals
110KV (300mm2) cable 800m
35KV (300mm2) cable 3000m
10KV(300mm2) cable 200m
110KV Full Insulated Transformer

SXBP-45/90/135/180/270-270

Test Frequency: 20~300Hz

110KV Insulator, switchgear, GIS and etc. 20KW 1 unit 20KW 1 unit

45KV/1A Six Units

Frequency: 20-300Hz

200KV
50MW/110KV Full Insulated Transformer
110KV (300mm2) cable 200m
35KV Power Transformer, switchgear, CT/PT, cable, and etc.
20MW hydrogenerator
10KV power transformer, switchgear, CT/PT, cables and etc.

SXBP18/36/54

Test Frequency: 20~300Hz

10KV (300mm2) cable 2000m 5KW 1 Unit 5KW 1 unit

27KV/1A 2 units or

18KV/1A 3 units

Frequency: 20-300Hz

60KV
35KV (300mm2) cable 500m
10KV power transformer, switchgear, CT/PT and etc.

√ Model SXBP-27/54/108-108, SXBP is the model of series, 27/54/108 is: voltage of one reactor (KV)/voltage of two reactors in series connection/voltage of four reactors in series connection. 108 is the total capacity (KVA).

√ The test object is the common configuration for reference only.

Specifications

√ Rated output voltage: 0~500kV or below

√ Output frequency: 20 -300Hz.

√ Quality factor: max. load ≥ 20.

√ Frequency adjustment: fineness 0.1Hz, instability ≤ 0.01%.

√ Resonant voltage waveform: sine wave, waveform Distortion rate ≤ 1%.

√ Full load working time: continuous working time 60mins.

√ Power supply: 220V or 380V single-phase.

Inquiry Cart 0